22/10/2026
Audi sq5 3.0 TFSI brought to us with a turbo fault.
During diagnosis we found the water pump was leaking and coolant had contaminated
Some of the vac lines and had traveled to the turbo pressure converters. These water pumps have a vac connection on them.
New genuine updated water pump, pressure converters, drive belt and vac lines cleaned out.
All back up and running and thoroughly tested to confirm fault fixed.
Happy days 😎🚘🔧💻